Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
J Appl Clin Med Phys ; 22(11): 12-20, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34664386

RESUMO

This study aimed to measure dose in a scanning carbon beam-irradiation field with high sampling rate that is sufficient for identifying spots and verifying the characteristics of the scanning beam that cannot generally be derived from the dose. To identify the spot, which is the smallest control unit of beam information during irradiation, effecting measurements with a sampling time of 10 µs or shorter is necessary. The provided dose within a specific time is referred to as time-resolved dose (TRD). We designed a circuit for time-resolved dosimetry using a fast-data acquisition unit (SL1000, Yokogawa Electric Co.), which can measure 100 000 samples per second. Moreover, we used converters to enable a connection between an ionization chamber (IC) and the SL1000. TRD was measured successfully using point irradiation and two-dimensional irradiation patterns in a scanned carbon beam. Based on the moving time of the spot obtained from the position monitor, the dose delivered to the IC from each spot position (spot dose) was interpreted. The spot dose, displacement of the chamber from the beam's center axis, and beam size were derived using TRD and position monitor outputs, which were measured concurrent with TRD. Spot dose up to a radius of 8 mm area from the IC's center were observed. Using the spot-dose equations and simulation, we show that the spot dose of each position varies depending on the beam size and displacement of the IC's center from the beam's center axis. We devise an interpretation method for the characteristics that may apply to quality assurance, such as the verification of the trend for the beam axis and isocenter to coincide, as well as beam-size verification.


Assuntos
Terapia com Prótons , Humanos , Controle de Qualidade , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
2.
Phys Med ; 52: 18-26, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30139605

RESUMO

INTRODUCTION: In the 7 years since our facility opened, we have treated >2000 patients with pencil-beam scanned carbon-ion beam therapy. METHODS: To summarize treatment workflow, we evaluated the following five metrics: i) total number of treated patients; ii) treatment planning time, not including contouring procedure; iii) quality assurance (QA) time (daily and patient-specific); iv) treatment room occupancy time, including patient setup, preparation time, and beam irradiation time; and v) daily treatment hours. These were derived from the oncology information system and patient handling system log files. RESULTS: The annual number of treated patients reached 594, 7 years from the facility startup, using two treatment rooms. Mean treatment planning time was 6.0 h (minimum: 3.4 h for prostate, maximum: 9.3 h for esophagus). Mean time devoted to daily QA and patient-specific QA were 22 min and 13.5 min per port, respectively, for the irradiation beam system. Room occupancy time was 14.5 min without gating for the first year, improving to 9.2 min (8.2 min without gating and 12.8 min with gating) in the second. At full capacity, the system ran for 7.5 h per day. CONCLUSIONS: We are now capable of treating approximately 600 patients per year in two treatment rooms. Accounting for the staff working time, this performance appears reasonable compared to the other facilities.


Assuntos
Radioterapia com Íons Pesados , Ensaios Clínicos como Assunto , Radioterapia com Íons Pesados/métodos , Humanos , Manutenção , Neoplasias/radioterapia , Garantia da Qualidade dos Cuidados de Saúde , Planejamento da Radioterapia Assistida por Computador , Fatores de Tempo , Fluxo de Trabalho
3.
Med Phys ; 43(4): 1754, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27036572

RESUMO

PURPOSE: Three-dimensional irradiation with a scanned carbon-ion beam has been performed from 2011 at the authors' facility. The authors have developed the rotating-gantry equipped with the scanning irradiation system. The number of combinations of beam properties to measure for the commissioning is more than 7200, i.e., 201 energy steps, 3 intensities, and 12 gantry angles. To compress the commissioning time, quick and simple range verification system is required. In this work, the authors develop a quick range verification system using scintillator and charge-coupled device (CCD) camera and estimate the accuracy of the range verification. METHODS: A cylindrical plastic scintillator block and a CCD camera were installed on the black box. The optical spatial resolution of the system is 0.2 mm/pixel. The camera control system was connected and communicates with the measurement system that is part of the scanning system. The range was determined by image processing. Reference range for each energy beam was determined by a difference of Gaussian (DOG) method and the 80% of distal dose of the depth-dose distribution that were measured by a large parallel-plate ionization chamber. The authors compared a threshold method and a DOG method. RESULTS: The authors found that the edge detection method (i.e., the DOG method) is best for the range detection. The accuracy of range detection using this system is within 0.2 mm, and the reproducibility of the same energy measurement is within 0.1 mm without setup error. CONCLUSIONS: The results of this study demonstrate that the authors' range check system is capable of quick and easy range verification with sufficient accuracy.


Assuntos
Equipamentos e Provisões Elétricas , Radioterapia com Íons Pesados/instrumentação , Contagem de Cintilação/instrumentação , Distribuição Normal , Controle de Qualidade , Dosagem Radioterapêutica , Fatores de Tempo
4.
Phys Med Biol ; 61(10): 3857-66, 2016 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-27100312

RESUMO

To shorten treatment time in pencil beam scanning irradiation, we developed rapid phase-controlled rescanning (rPCR), which irradiates two or more isoenergy layers in a single gating window. Here, we evaluated carbon-ion beam dose distribution with rapid and conventional PCR (cPCR). 4 dimensional computed tomography (4DCT) imaging was performed on 12 subjects with lung or liver tumors. To compensate for intrafractional range variation, the field-specific target volume (FTV) was calculated using 4DCT within the gating window (T20-T80). We applied an amplitude-based gating strategy, in which the beam is on when the tumor is within the gating window defined by treatment planning. Dose distributions were calculated for layered phase-controlled rescanning under an irregular respiratory pattern, although a single 4DCT data set was used. The number of rescannings was eight times. The prescribed doses were 48 Gy(RBE)/1 fr (where RBE is relative biological effectiveness) delivered via four beam ports to the FTV for the lung cases and 45 Gy(RBE)/2 fr delivered via two beam ports to the FTV for the liver cases. In the liver cases, the accumulated dose distributions showed an increased magnitude of hot/cold spots with rPCR compared with cPCR. The results of the dose assessment metrics for the cPCR and rPCR were very similar. The D 95, D max, and D min values (cPCR/rPCR) averaged over all the patients were 96.3 ± 0.9%/96.0 ± 1.2%, 107.3 ± 3.6%/107.1 ± 2.9%, and 88.8 ± 3.2%/88.1 ± 3.1%, respectively. The treatment times in cPCR and rPCR were 110.7 s and 53.5 s, respectively. rPCR preserved dose conformation under irregular respiratory motion and reduced the total treatment time compared with cPCR.


Assuntos
Radioterapia com Íons Pesados/métodos , Neoplasias Hepáticas/radioterapia , Neoplasias Pulmonares/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Respiração , Idoso , Idoso de 80 Anos ou mais , Feminino , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Doses de Radiação
5.
Med Phys ; 43(2): 635-42, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26843227

RESUMO

PURPOSE: Accurate dose measurement in radiotherapy is critically dependent on correction for gain drop, which is the difference of the measured current from the ideal saturation current due to general ion recombination. Although a correction method based on the Boag theory has been employed, the theory assumes that ionized charge density in an ionization chamber (IC) is spatially uniform throughout the irradiation volume. For particle pencil beam scanning, however, the charge density is not uniform, because the fluence distribution of a pencil beam is not uniform. The aim of this study was to verify the effect of the nonuniformity of ionized charge density on the gain drop due to general ion recombination. METHODS: The authors measured the saturation curve, namely, the applied voltage versus measured current, using a large plane-parallel IC and 24-channel parallel-plate IC with concentric electrodes. To verify the effect of the nonuniform ionized charge density on the measured saturation curve, the authors calculated the saturation curve using a method which takes into account the nonuniform ionized charge density and compared it with the measured saturation curves. RESULTS: Measurement values of the different saturation curves in the different channels of the concentric electrodes differed and were consistent with the calculated values. The saturation curves measured by the large plane-parallel IC were also consistent with the calculation results, including the estimation error of beam size and of setup misalignment. Although the impact of the nonuniform ionized charge density on the gain drop was clinically negligible with the conventional beam intensity, it was expected that the impact would increase with higher ionized charge density. CONCLUSIONS: For pencil beam scanning, the assumption of the conventional Boag theory is not valid. Furthermore, the nonuniform ionized charge density affects the prediction accuracy of gain drop when the ionized charge density is increased by a higher dose rate and/or lower beam size.


Assuntos
Radioterapia com Íons Pesados , Radiometria/métodos , Dosagem Radioterapêutica
6.
Radiat Oncol ; 9: 238, 2014 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-25384996

RESUMO

BACKGROUND: To moving lung tumors, we applied a respiratory-gated strategy to carbon-ion pencil beam scanning with multiple phase-controlled rescanning (PCR). In this simulation study, we quantitatively evaluated dose distributions based on 4-dimensional CT (4DCT) treatment planning. METHODS: Volumetric 4DCTs were acquired for 14 patients with lung tumors. Gross tumor volume, clinical target volume (CTV) and organs at risk (OARs) were delineated. Field-specific target volumes (FTVs) were calculated, and 48Gy(RBE) in a single fraction was prescribed to the FTVs delivered from four beam angles. The dose assessment metrics were quantified by changing the number of PCR and the results for the ungated and gated scenarios were then compared. RESULTS: For the ungated strategy, the mean dose delivered to 95% of the volume of the CTV (CTV-D95) was in average 45.3 ± 0.9 Gy(RBE) even with a single rescanning (1 × PCR). Using 4 × PCR or more achieved adequate target coverage (CTV-D95 = 46.6 ± 0.3 Gy(RBE) for ungated 4 × PCR) and excellent dose homogeneity (homogeneity index =1.0 ± 0.2% for ungated 4 × PCR). Applying respiratory gating, percentage of lung receiving at least 20 Gy(RBE) (lung-V20) and heart maximal dose, averaged over all patients, significantly decreased by 12% (p < 0.05) and 13% (p < 0.05), respectively. CONCLUSIONS: Four or more PCR during PBS-CIRT improved dose conformation to moving lung tumors without gating. The use of a respiratory-gated strategy in combination with PCR reduced excessive doses to OARs.


Assuntos
Carbono/uso terapêutico , Simulação por Computador , Tomografia Computadorizada Quadridimensional/métodos , Radioterapia com Íons Pesados , Neoplasias Pulmonares/radioterapia , Planejamento da Radioterapia Assistida por Computador/instrumentação , Radioterapia Guiada por Imagem/métodos , Técnicas de Imagem de Sincronização Respiratória/instrumentação , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Órgãos em Risco/efeitos da radiação , Prognóstico , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada , Técnicas de Imagem de Sincronização Respiratória/métodos
7.
J Radiat Res ; 55(5): 948-58, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24835238

RESUMO

Amplitude-based gating aids treatment planning in scanned particle therapy because it gives better control of uncertainty with the gate window. We have installed an X-ray fluoroscopic imaging system in our treatment room for clinical use with an amplitude-based gating strategy. We evaluated the effects of this gating under realistic organ motion conditions using 4 DCT data of lung and liver tumors. 4 DCT imaging was done for 24 lung and liver patients using the area-detector CT. We calculated the field-specific target volume (FTV) for the gating window, which was defined for a single respiratory cycle. Prescribed doses of 48 Gy relative biological effectiveness (RBE)/fraction/four fields and 45 Gy RBE/two fractions/two fields were delivered to the FTVs for lung and liver treatments, respectively. Dose distributions were calculated for the repeated first respiratory cycle (= planning dose) and the whole respiratory data (= treatment dose). We applied eight phase-controlled rescannings with the amplitude-based gating. For the lung cases, D95 of the treatment dose (= 96.0 ± 1.0%) was almost the same as that of the planning dose (= 96.6 ± 0.9%). D(max)/D(min) of the treatment dose (= 104.5 ± 2.2%/89.4 ± 2.6%) was slightly increased over that of the planning dose (= 102.1 ± 1.0%/89.8 ± 2.5%) due to hot spots. For the liver cases, D95 of the treatment dose (= 97.6 ± 0.5%) was decreased by ∼ 1% when compared with the planning dose (= 98.5 ± 0.4%). D(max)/D(min) of the treatment dose was degraded by 3.0%/0.4% compared with the planning dose. Average treatment times were extended by 46.5 s and 65.9 s from those of the planning dose for lung and liver cases, respectively. As with regular respiratory patterns, amplitude-based gated multiple phase-controlled rescanning preserves target coverage to a moving target under irregular respiratory patterns.


Assuntos
Tomografia Computadorizada Quadridimensional/métodos , Radioterapia com Íons Pesados/métodos , Neoplasias Hepáticas/radioterapia , Neoplasias Pulmonares/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Idoso , Idoso de 80 Anos ou mais , Carbono , Feminino , Humanos , Íons , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
8.
Radiother Oncol ; 111(3): 431-6, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24785510

RESUMO

PURPOSE: Pencil beam scanning offers excellent conformity, but is sensitive to organ motion. We conducted a simulation study to validate our rescanning approach in combination with gating in the irradiation of liver tumors. MATERIALS AND METHODS: 4DCT imaging was performed under free-breathing conditions in 30 patients with hepatocellular carcinoma. Dose distributions for a two-field approach were calculated for layered phase controlled rescannings (PCR) under organ motion conditions. A total dose of 45 Gy(RBE) was delivered to respective field-specific target volumes (FTVs) in two fractions, each composed of two orthogonal uniform fields of 11.25 Gy(RBE) at beam angles of either 0° and 90° or 0° and 270°. The number of rescannings was changed from 1 to 10. RESULTS: Good dose conformity was achieved with 4× PCR or more, and over 95% of the prescribed dose was delivered to the CTV independent of the use of gating. D95, Dmax/min and dose homogeneity were similar with or without gating, whereas V10 dose to the liver as well as maximal doses to healthy tissue (esophagus and cord) were about 40% lower with gating. However, total time increased by about 50% with gating. CONCLUSIONS: Gated rescanning provides good target coverage and homogeneity with maximal sparing of healthy tissue. Our results suggest that carbon-ion pencil beam scanning may soon be available for the safe treatment of liver tumors.


Assuntos
Neoplasias Hepáticas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Carbono/química , Simulação por Computador , Fracionamento da Dose de Radiação , Humanos , Processamento de Imagem Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/instrumentação , Radioterapia de Alta Energia , Respiração
9.
Med Phys ; 41(2): 021706, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24506597

RESUMO

PURPOSE: It is essential to consider large-angle scattered particles in dose calculation models for therapeutic carbon-ion beams. However, it is difficult to measure the small dose contribution from large-angle scattered particles. In this paper, the authors present a novel method to derive the parameters describing large-angle scattered particles from the measured results. METHODS: The authors developed a new parallel-plate ionization chamber consisting of concentric electrodes. Since the sensitive volume of each channel is increased linearly with this type, it is possible to efficiently and easily detect small contributions from the large-angle scattered particles. The parameters describing the large-angle scattered particles were derived from pencil beam dose distribution in water measured with the new ionization chamber. To evaluate the validity of this method, the correction for the field-size dependence of the doses, "predicted-dose scaling factor," was calculated with the new parameters. RESULTS: The predicted-dose scaling factor calculated with the new parameters was compared with the existing one. The difference between the new correction factor and the existing one was 1.3%. For target volumes of different sizes, the calculated dose distribution with the new parameters was in good agreement with the measured one. CONCLUSIONS: Parameters describing the large-angle scattered particles can be efficiently and rapidly determined using the new ionization chamber. The authors confirmed that the field-size dependence of the doses could be compensated for by the new parameters. This method makes it possible to easily derive the parameters describing the large-angle scattered particles, while maintaining the dose calculation accuracy.


Assuntos
Radioterapia com Íons Pesados/métodos , Espalhamento de Radiação , Eletrodos , Radiometria , Dosagem Radioterapêutica , Reprodutibilidade dos Testes
10.
Med Phys ; 40(12): 121707, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24320493

RESUMO

PURPOSE: To evaluate a patient-specific QA program and system for constancy checking of a scanning delivery system developed at the National Institute of Radiological Sciences. METHODS: For the patient-specific QA, all the planned beams are recalculated on a water phantom with treatment planning software (TPS). The recalculated dose distributions are compared with the measured distributions using a 2D ionization chamber array at several depths, and evaluated using gamma index analysis with criteria of 3% and 3 mm and a pass rate of 90%. For the constancy check, the authors developed the multiwire proportional chamber (MWPC), which can record the delivered 2D fluence images in a slice-by-slice manner. During irradiation for dosimetric QA with the 2D ionization chamber array and an accordion-type water phantom, the 2D fluence images are recorded using the MWPC in the delivery system. These recorded images are then compared to those taken in the treatment session to check the constancy check. This analysis also employs gamma index analysis using the same criteria as in the patient-specific QA. These patient-specific QA and constancy check evaluations were performed using the data of 122 patients. RESULTS: In the patient-specific QA, the measured dose distributions agreed well with those calculated by the TPS, and the QA criteria were satisfied in all measurements. The additional check of the fluence comparison ensured the constancy of the delivered field during each treatment irradiation. CONCLUSIONS: The authors established a patient-specific QA program and additional check of delivery constancy in every treatment session. Fluence comparison is a strong tool for constancy checking of the delivery system.


Assuntos
Radioterapia com Íons Pesados/métodos , Aceleradores de Partículas , Medicina de Precisão/métodos , Garantia da Qualidade dos Cuidados de Saúde/métodos , Radioterapia com Íons Pesados/instrumentação , Humanos , Neoplasias/radioterapia , Medicina de Precisão/instrumentação
11.
Radiat Res ; 180(1): 44-59, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23768075

RESUMO

Treatment plans of carbon-ion radiotherapy have been made on the assumption that the beams are delivered instantaneously irrespective to the dose delivery time as well as the interruption time. The advanced therapeutic techniques such as a hypofractionation and a respiratory gating usually require more time to deliver a fractioned dose than conventional techniques. The purpose of this study was to investigate the effects of dose-delivery time structure on biological effectiveness in carbon-ion radiotherapy. The rate equations defined in the microdosimetric kinetic model (MKM) for primary lesions caused in the DNA were reanalyzed and applied to continuous or interrupted irradiation with therapeutic carbon-ion beams. The rate constants characterizing the time of the primary nonlethal lesions to repair or to convert to lethal lesion were experimentally determined for human salivary gland (HSG) tumor cells. Treatment plans were made for a patient case on the assumption that the beam is delivered instantaneously. The RBE weighted absorbed doses of 2.65, 3.45 and 6.86 Gy (RBE) was prescribed to the target. These plans were recalculated by varying the dose delivery time and the interruption time ranging from 1-60 min based on the MKM with the determined parameters. The sum of rate constants for nonlethal lesion to repair a and to convert to lethal lesion c, (a + c), is 2.19 ± 0.40 h⁻¹. The biological effectiveness in the target decreases with the dose delivery time T in continuous irradiation compared to the planned one due to the repair of nonlethal lesions during the irradiation. The biological effectiveness in terms of equivalent acute dose decreases to 99.7% and 96.4% for T = 3 and 60 min in 2.65 Gy (RBE), 99.5% and 94.3% in 4.35 Gy (RBE), and 99.4% and 91.7% in 6.86 Gy (RBE), respectively. For all the cases, the decrease of biological effectiveness is larger at the proximal side with low-LET than the distal side with high-LET. Similar reductions of biological effectiveness with comparable amounts are observed in the interrupted irradiations with prolonged interruption time τ. For the fraction time, i.e., T and/or τ, shorter than 3 min, the decrease of the biological effectiveness with respect to the planned one is less than 1.0%. However, if the fraction time prolongs to 30 min or longer, the biological effectiveness is significantly influenced in carbon-ion radiotherapy, especially with high-prescribed doses. These effects, if confirmed by clinical studies, should be considered in designing the carbon-ion treatment planning.


Assuntos
Radioisótopos de Carbono/uso terapêutico , Dano ao DNA/efeitos da radiação , Modelos Teóricos , Eficiência Biológica Relativa , Relação Dose-Resposta à Radiação , Humanos , Cinética
12.
Med Phys ; 40(3): 031720, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23464315

RESUMO

PURPOSE: Irradiation of a moving target with a scanning beam requires a comprehensive understanding of organ motion as well as a robust dose error mitigation technique. The authors studied the effects of intrafractional respiratory motion for carbon-ion pencil beam scanning with phase-controlled rescanning on dose distributions for lung tumors. To address density variations, they used 4DCT data. METHODS: Dose distributions for various rescanning methods, such as simple layer rescanning (LR), volumetric rescanning, and phase-controlled rescanning (PCR), were calculated for a lung phantom and a lung patient studies. To ensure realism, they set the scanning parameters such as scanning velocity and energy variation time to be similar to those used at our institution. Evaluation metrics were determined with regard to clinical relevance, and consisted of (i) phase-controlled rescanning, (ii) sweep direction, (iii) target motion (direction and amplitude), (iv) respiratory cycle, and (v) prescribed dose. Spot weight maps were calculated by using a beam field-specific target volume, which takes account of range variations for respective respiratory phases. To emphasize the impact of intrafractional motion on the dose distribution, respiratory gating was not used. The accumulated dose was calculated by applying a B-spline-based deformable image registration, and the results for phase-controlled layered rescanning (PCRL) and phase-controlled volumetric rescanning (PCRV) were compared. RESULTS: For the phantom study, simple LR was unable to improve the dose distributions for an increased number of rescannings. The phase-controlled technique without rescanning (1×PCRL and 1×PCRV) degraded dose conformity significantly due to a reduced scan velocity. In contrast, 4×PCRL or more significantly and consistently improved dose distribution. PCRV showed interference effects, but in general also improved dose homogeneity with higher numbers of rescannings. Dose distributions with single PCRL∕PCRV with a sweep direction perpendicular to motion direction showed large hot∕cold spots; however, this effect vanished with higher numbers of rescannings for both methods. Similar observations were obtained for the other dose metrics, such as target motion (SI∕AP), amplitude (6-22 mm peak-to-peak) and respiratory period (3.0-5.0 s). For four or more rescannings, both methods showed significantly better results, albeit that volumetric PCR was more affected by interference effects, which lead to severe degradation of a few dose distributions. The clinical example showed the same tendencies as the phantom study. Dose assessment metrics (D95, Dmax∕Dmin, homogeneity index) were improved with an increasing number of PCRL∕PCRV, but with PCRL being more robust. CONCLUSIONS: PCRL requires a longer treatment time than PCRV for high numbers of rescannings in the NIRS scanning system but is more robust. Although four or more rescans provided good dose homogeneity and conformity, the authors prefer to use more rescannings for clinical cases to further minimize dose degradation effects due to organ motion.


Assuntos
Tomografia Computadorizada Quadridimensional/métodos , Radioterapia com Íons Pesados/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Fracionamento da Dose de Radiação , Humanos , Neoplasias Pulmonares/fisiopatologia , Movimento , Imagens de Fantasmas , Respiração
13.
J Appl Clin Med Phys ; 13(6): 3926, 2012 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-23149784

RESUMO

Our institution established a new treatment facility for carbon ion beam scanning therapy in 2010. The major advantages of scanning beam treatment compared to the passive beam treatment are the following: high dose conformation with less excessive dose to the normal tissues, no bolus compensator and patient collimator/multi-leaf collimator, better dose efficiency by reducing the number of scatters. The new facility was designed to solve several problems encountered in the existing facility, at which several thousand patients were treated over more than 15 years. Here, we introduce the patient handling system in the new treatment facility. The new facility incorporates three main systems, a scanning irradiation system (S-IR), treatment planning system (TPS), and patient handling system (PTH). The PTH covers a wide range of functions including imaging, geometrical/position accuracy including motion management (immobilization, robotic arm treatment bed), layout of the treatment room, treatment workflow, software, and others. The first clinical trials without respiratory gating have been successfully started. The PTH allows a reduction in patient stay in the treatment room to as few as 7 min. The PTH plays an important role in carbon ion beam scanning therapy at the new institution, particularly in the management of patient handling, application of image-guided therapy, and improvement of treatment workflow, and thereby allows substantially better treatment at minimum cost.


Assuntos
Carbono/uso terapêutico , Desenho de Equipamento , Radioterapia com Íons Pesados/instrumentação , Movimentação e Reposicionamento de Pacientes , Neoplasias/radioterapia , Planejamento da Radioterapia Assistida por Computador/instrumentação , Ensaios Clínicos como Assunto , Arquitetura de Instituições de Saúde , Humanos , Imobilização , Garantia da Qualidade dos Cuidados de Saúde , Radioterapia de Intensidade Modulada , Robótica
14.
J Radiat Res ; 53(5): 760-8, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22927632

RESUMO

Our institute has constructed a new treatment facility for carbon ion scanning beam therapy. The first clinical trials were successfully completed at the end of November 2011. To evaluate patient setup accuracy, positional errors between the reference Computed Tomography (CT) scan and final patient setup images were calculated using 2D-3D registration software. Eleven patients with tumors of the head and neck, prostate and pelvis receiving carbon ion scanning beam treatment participated. The patient setup process takes orthogonal X-ray flat panel detector (FPD) images and the therapists adjust the patient table position in six degrees of freedom to register the reference position by manual or auto- (or both) registration functions. We calculated residual positional errors with the 2D-3D auto-registration function using the final patient setup orthogonal FPD images and treatment planning CT data. Residual error averaged over all patients in each fraction decreased from the initial to the last treatment fraction [1.09 mm/0.76° (averaged in the 1st and 2nd fractions) to 0.77 mm/0.61° (averaged in the 15th and 16th fractions)]. 2D-3D registration calculation time was 8.0 s on average throughout the treatment course. Residual errors in translation and rotation averaged over all patients as a function of date decreased with the passage of time (1.6 mm/1.2° in May 2011 to 0.4 mm/0.2° in December 2011). This retrospective residual positional error analysis shows that the accuracy of patient setup during the first clinical trials of carbon ion beam scanning therapy was good and improved with increasing therapist experience.


Assuntos
Radioterapia com Íons Pesados , Feminino , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Radioterapia com Íons Pesados/instrumentação , Radioterapia com Íons Pesados/estatística & dados numéricos , Humanos , Masculino , Posicionamento do Paciente/estatística & dados numéricos , Neoplasias Pélvicas/diagnóstico por imagem , Neoplasias Pélvicas/radioterapia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
15.
Australas Phys Eng Sci Med ; 35(2): 221-9, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22711446

RESUMO

To increase the accuracy of carbon ion beam scanning therapy, we have developed a graphical user interface-based digitally-reconstructed radiograph (DRR) software system for use in routine clinical practice at our center. The DRR software is used in particular scenarios in the new treatment facility to achieve the same level of geometrical accuracy at the treatment as at the imaging session. DRR calculation is implemented simply as the summation of CT image voxel values along the X-ray projection ray. Since we implemented graphics processing unit-based computation, the DRR images are calculated with a speed sufficient for the particular clinical practice requirements. Since high spatial resolution flat panel detector (FPD) images should be registered to the reference DRR images in patient setup process in any scenarios, the DRR images also needs higher spatial resolution close to that of FPD images. To overcome the limitation of the CT spatial resolution imposed by the CT voxel size, we applied image processing to improve the calculated DRR spatial resolution. The DRR software introduced here enabled patient positioning with sufficient accuracy for the implementation of carbon-ion beam scanning therapy at our center.


Assuntos
Algoritmos , Radioterapia com Íons Pesados , Intensificação de Imagem Radiográfica/métodos , Radioterapia Guiada por Imagem/métodos , Software , Carbono , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Med Phys ; 39(5): 2820-5, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22559653

RESUMO

PURPOSE: In radiotherapy with a scanned carbon-ion beam, its Bragg peak is shifted along the depth direction either by inserting the range shifter plates or by changing the beam-extraction energy of a synchrotron. In the former technique (range shifter scanning: RS), the range shifter plates broaden the beam size and produce secondary fragments through nuclear reactions. In the latter technique (active-energy scanning: ES), it may take several seconds to change the beam energy depending on the synchrotron operation cycle, leading to a long treatment time. The authors propose a hybrid depth scan technique (hybrid scanning: HS), where several beam energies are used in conjunction with the range shifter plates for finer range shift. In this study, HS is evaluated from the viewpoints of dose distribution and treatment time. METHODS: Assuming realistic accelerator and beam-delivery systems, the authors performed computer simulations using GEANT4 Monte Carlo code for beam modeling and a treatment planning system to evaluate HS. Three target volumes with the same dimensions of 60 × 60 × 60 mm(3) were generated at depths of 45, 85, and 125 mm in water phantom, and uniform clinical dose was planned for these targets. The sizes of lateral dose falloff and the peak to plateau ratio defined as the ratio of the clinical dose averaged over the target to the clinical dose at the entrance as well as the treatment time were compared among the three depth scan techniques. RESULTS: The sizes of lateral dose falloffs at the center of SOBP are 11.4, 8.5, and 5.9 mm for the three targets in RS, while they are 5.7, 4.8, and 4.6 mm in ES and 6.6, 5.7, and 5.0 mm in HS, respectively. The peak to plateau ratios are 1.39, 1.96, and 2.15 in RS, while they are 1.48, 2.04, and 2.19 in ES and 1.47, 2.03, and 2.18 in HS, respectively. The treatment times are 128.7, 128.6, and 128.6 s in ES, while they are 61.2, 54.6, and 47.8 s in RS and 43.2, 44.1, and 44.7 s in HS, respectively. The multiple scattering and the nuclear reaction by range shifter degraded the beam qualities such as lateral dose falloff and peak to plateau ratio, which was especially pronounced for the shallow target in RS. The depth scan timing was limited by accelerator cycle in ES. That increased the treatment time by a few times. CONCLUSIONS: This study revealed that HS can provide dose distributions with steeper lateral dose falloffs and higher peak to plateau ratio comparing to RS and comparable to ES. In addition, the treatment time can be considerably reduced in HS compared to ES.


Assuntos
Carbono/uso terapêutico , Radioterapia Assistida por Computador/métodos , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Fatores de Tempo
17.
Phys Med Biol ; 56(15): 4749-70, 2011 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-21753233

RESUMO

Intensity modulated proton therapy (IMPT) offers the possibility of generating excellent target coverage while sparing the neighbouring organs at risk. However, treatment plans optimized for IMPT may be very sensitive to range and setup uncertainties. We developed a method to deal with these uncertainties in the dose optimization. This method aims at two objectives: one for maintaining the dose coverage within the target, and the other for preventing undesired exposure to organs at risk. The former objective was achieved by the algorithm described in our previous paper to suppress the in-field dose gradient within the target. In this study, the latter objective was achieved by a novel algorithm in which we suppressed pencil beams with high risk to deliver undesired doses to organs at risk under conditions where range and setup uncertainties occur. We defined the risk index that quantifies the likelihood of each pencil beam delivering high doses to organs at risk, and introduced it into the objective function of dose optimizations. In order to test the algorithm's performance, this method was applied to an RTOG benchmark phantom geometry and to a cervical chordoma case. These simulations demonstrated that our method provides IMPT plans that are more robust against range and setup errors compared to conventional IMPT plans. Compared to the conventional IMPT plan, the optimization time for the robust plan increased by a factor of only 3, from 4 to 11 min.


Assuntos
Algoritmos , Órgãos em Risco/efeitos da radiação , Terapia com Prótons , Prótons/efeitos adversos , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Benchmarking , Cordoma/radioterapia , Feminino , Humanos , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador , Software , Incerteza , Neoplasias do Colo do Útero/radioterapia
18.
Rev Sci Instrum ; 82(5): 053303, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21639496

RESUMO

A gain reduction process caused by successive beam irradiation in a multi-wire proportional chamber was numerically investigated to clarify the relations between the gas gain variation and the ion density distribution. A numerical code was developed based on a two-dimensional drift-diffusion model in order to evaluate the ion and electron density distributions and the electric field variation caused by the space charge effect. In order to consider the gain reduction process which occurs under the high rate and successive irradiation, the simulations were performed for the time period of ∼10-100 µs, which is much longer than the time required for ions to travel from an anode to a cathode. The numerical simulation results showed that for the low gas gain regime of ∼10, quasi-stationary density distribution of the ions was formed by the high-rate beams of ∼10(8)-10(10) particles per second, and that the transient variation of the gas gain became constant after establishment of the quasi-stationary ion density distributions.

19.
Phys Med Biol ; 56(6): 1653-69, 2011 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-21346278

RESUMO

A 'patch-field' strategy is often used for tumors with large volumes exceeding the available field size in passive irradiations with ion beams. Range and setup errors can cause hot and cold spots at the field junction within the target. Such errors will also displace the field to miss the target periphery. With scanned ion beams with fluence modulation, the two junctional fields can be overlapped rather than patched, which may potentially reduce the sensitivity to these uncertainties. In this study, we have developed such a robust optimization algorithm. This algorithm is composed of the following two steps: (1) expanding the target volume with margins against the uncertainties, and (2) solving the inverse problem where the terms suppressing the dose gradient of individual fields are added into the objective function. The validity of this algorithm is demonstrated through simulation studies for two extreme cases of two fields with unidirectional and opposing geometries and for a prostate-cancer case. With the proposed algorithm, we can obtain a more robust plan with minimized influence of range and setup uncertainties than the conventional plan. Compared to conventional optimization, the calculation time for the robust optimization increased by a factor of approximately 3.


Assuntos
Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Simulação por Computador , Humanos , Íons , Masculino , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Incerteza
20.
Med Phys ; 37(11): 5672-82, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21158279

RESUMO

PURPOSE: A project to construct a new treatment facility, as an extension of the existing HIMAC facility, has been initiated for the further development of carbon-ion therapy at NIRS. This new treatment facility is equipped with a 3D irradiation system with pencil-beam scanning. The challenge of this project is to realize treatment of a moving target by scanning irradiation. To achieve fast rescanning within an acceptable irradiation time, the authors developed a fast scanning system. METHODS: In order to verify the validity of the design and to demonstrate the performance of the fast scanning prior to use in the new treatment facility, a new scanning-irradiation system was developed and installed into the existing HIMAC physics-experiment course. The authors made strong efforts to develop (1) the fast scanning magnet and its power supply, (2) the high-speed control system, and (3) the beam monitoring. The performance of the system including 3D dose conformation was tested by using the carbon beam from the HIMAC accelerator. RESULTS: The performance of the fast scanning system was verified by beam tests. Precision of the scanned beam position was less than +/-0.5 mm. By cooperating with the planning software, the authors verified the homogeneity of the delivered field within +/-3% for the 3D delivery. This system took only 20 s to deliver the physical dose of 1 Gy to a spherical target having a diameter of 60 mm with eight rescans. In this test, the average of the spot-staying time was considerably reduced to 154 micros, while the minimum staying time was 30 micros. CONCLUSIONS: As a result of this study, the authors verified that the new scanning delivery system can produce an accurate 3D dose distribution for the target volume in combination with the planning software.


Assuntos
Radioterapia com Íons Pesados , Radioterapia (Especialidade)/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Relação Dose-Resposta à Radiação , Campos Eletromagnéticos , Desenho de Equipamento , Humanos , Imageamento Tridimensional , Magnetismo , Doses de Radiação , Software , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...